{
  "formatVersion": "1.0",
  "language": "en",
  "url": "https://megafeis.com/split-cab-display",
  "jsonUrl": "https://megafeis.com/data/pages/split-cab-display.json",
  "kind": "product",
  "title": "Split Cab Display",
  "description": "Split cab-display terminal for locomotive operating data, track-ahead and running-gear event imagery, equipment alarms, live video, and offline record review.",
  "content": {
    "url": "https://megafeis.com/split-cab-display",
    "kicker": "Cab display and operator interface",
    "productName": "Split Cab Display",
    "shortName": "Split Cab Display",
    "title": "Split Cab Display",
    "overview": "A cab HMI comprising an industrial display and an optional AI-enabled base. It is designed for DC46–160 V locomotive power and can interface with vehicle-control, event-recorder, and onboard data systems. The display brings together live video, operating data, and alarms; the optional base supports lightweight engineer-monitoring analytics and presents track-ahead and running-gear event imagery produced by the onboard computer.",
    "primaryCta": "View key parameters & features",
    "mainImage": "/megafeis-images/split-cab-display-main.png",
    "mainImageAlt": "Locomotive split cab display terminal",
    "sceneImage": "/megafeis-images/split-cab-display-cab.png",
    "sceneImageAlt": "Split cab display installed in a locomotive cab",
    "highlights": [
      "High-brightness industrial display",
      "Optional AI-enabled base",
      "DC46–160 V input"
    ],
    "capabilitiesTitle": "Core Functions",
    "capabilitiesDescription": "A single cab display for locomotive operating data, event imagery, engineer warnings, equipment alarms, and cached records.",
    "capabilities": [
      {
        "title": "Cab Operating Display",
        "body": "Shows available speed and location data alongside high-resolution event imagery for track-ahead hazards and running-gear conditions identified by the onboard computer."
      },
      {
        "title": "Engineer-Monitoring Alerts",
        "body": "The optional AI-enabled base can support selected cab-monitoring functions, such as attentiveness and seat-occupancy detection, subject to the vehicle program and validation plan."
      },
      {
        "title": "Live Video Preview",
        "body": "The integrated switch can feed line and undercarriage cameras to the cab display for live forward-view and undercarriage imagery."
      },
      {
        "title": "Integrated Safety Alerts",
        "body": "Brings vehicle-system faults together with track-ahead and running-gear event alerts in one cab workflow."
      },
      {
        "title": "Time-Stamped Evidence",
        "body": "Applies a common time reference to images and operating data, keeping line-risk and undercarriage snapshots traceable for investigation and review."
      },
      {
        "title": "Store-and-Forward Transfer",
        "body": "Stores line and undercarriage snapshots during coverage gaps and forwards them through the onboard data gateway when connectivity returns."
      }
    ],
    "scenariosTitle": "Application Scenarios",
    "scenariosDescription": "A cab terminal for reviewing local-analysis results and supporting timely response to track-ahead and running-gear events.",
    "scenarios": [
      "Real-time cab review of warning imagery for track obstructions, rockfall, and right-of-way intrusion ahead.",
      "Reviewing running-gear inspection imagery captured under the approved operating conditions.",
      "Clear presentation of onboard-computer alerts to support a prompt response to track-ahead and running-gear events."
    ],
    "specsTitle": "Core Parameters",
    "specCategoryLabel": "Module",
    "specItemLabel": "Parameter",
    "specDetailLabel": "Specification",
    "specGroups": [
      {
        "title": "Display and Onboard Integration",
        "rows": [
          [
            "Industrial display",
            "10.1-inch high-brightness touchscreen with glove touch and anti-glare treatment"
          ],
          [
            "Onboard integration",
            "Display and alarm integration with vehicle-control, event-recorder, data-gateway, and other onboard systems"
          ],
          [
            "Locomotive power",
            "DC46–160 V locomotive input"
          ]
        ]
      },
      {
        "title": "Optional AI Compute Base",
        "rows": [
          [
            "AI behavior analytics",
            "Optional local AI processing for selected locomotive engineer-monitoring functions"
          ],
          [
            "Switching and interfaces",
            "Integrated onboard switching, locking circular connectors and CAN/RS485 interfaces"
          ]
        ]
      }
    ],
    "complianceTitle": "Compliance Standards",
    "compliance": "Designed for applicable railway environmental, EMC, and fire-performance requirements. Final compliance depends on the product configuration, vehicle integration, and project validation.",
    "faqDescription": "Selection guidance for locomotive cab displays, base configurations and data continuity through coverage gaps."
  },
  "faqs": [
    {
      "question": "Why cannot a standard industrial tablet replace a dedicated locomotive onboard tablet?",
      "answer": "A standard industrial tablet may not include the locomotive power, vibration, temperature, and EMC design needed for the vehicle environment. It may also lack the vehicle interfaces, common timing, and event-record workflow required by an integrated onboard system."
    },
    {
      "question": "How do the tablet base and onboard computer divide computing work?",
      "answer": "The standard base provides switching, power, and device access. The AI-enhanced base can support lightweight cab-monitoring functions, while the onboard computer performs deeper track-ahead and running-gear analytics."
    },
    {
      "question": "How is event data handled during a communications outage?",
      "answer": "When configured with local storage, the tablet can retain event imagery in disconnected territory and synchronize records through the onboard data gateway after connectivity returns."
    }
  ],
  "structuredData": [
    {
      "@context": "https://schema.org",
      "@graph": [
        {
          "@type": "Organization",
          "@id": "https://megafeis.com/#organization",
          "name": "MegaFeis",
          "alternateName": "MEGAFEIS",
          "legalName": "MegaFeis",
          "url": "https://megafeis.com",
          "description": "Split cab-display terminal for locomotive operating data, track-ahead and running-gear event imagery, equipment alarms, live video, and offline record review.",
          "logo": "https://megafeis.com/megafeis-favicon.svg",
          "email": "info@megafeis.com",
          "address": {
            "@type": "PostalAddress",
            "streetAddress": "Raleigh, NC 27606",
            "addressLocality": "Raleigh",
            "addressRegion": "NC",
            "addressCountry": "US"
          },
          "contactPoint": [
            {
              "@type": "ContactPoint",
              "contactType": "Sales",
              "email": "sales@megafeis.com",
              "availableLanguage": [
                "English"
              ]
            },
            {
              "@type": "ContactPoint",
              "contactType": "After-sales support",
              "email": "service@megafeis.com",
              "availableLanguage": [
                "English"
              ]
            },
            {
              "@type": "ContactPoint",
              "contactType": "General enquiries",
              "email": "info@megafeis.com",
              "availableLanguage": [
                "English"
              ]
            }
          ]
        },
        {
          "@type": "WebSite",
          "@id": "https://megafeis.com/#website",
          "name": "MEGAFEIS",
          "url": "https://megafeis.com",
          "inLanguage": "en",
          "publisher": {
            "@id": "https://megafeis.com/#organization"
          }
        }
      ]
    },
    {
      "@context": "https://schema.org",
      "@type": "Product",
      "@id": "https://megafeis.com/split-cab-display#product",
      "name": "Split Cab Display",
      "description": "A cab HMI comprising an industrial display and an optional AI-enabled base. It is designed for DC46–160 V locomotive power and can interface with vehicle-control, event-recorder, and onboard data systems. The display brings together live video, operating data, and alarms; the optional base supports lightweight engineer-monitoring analytics and presents track-ahead and running-gear event imagery produced by the onboard computer.",
      "image": [
        "https://megafeis.com/megafeis-images/split-cab-display-main.png",
        "https://megafeis.com/megafeis-images/split-cab-display-cab.png"
      ],
      "url": "https://megafeis.com/split-cab-display",
      "brand": {
        "@type": "Brand",
        "name": "MEGAFEIS"
      },
      "additionalProperty": [
        {
          "@type": "PropertyValue",
          "name": "Display and Onboard Integration · Industrial display",
          "value": "10.1-inch high-brightness touchscreen with glove touch and anti-glare treatment"
        },
        {
          "@type": "PropertyValue",
          "name": "Display and Onboard Integration · Onboard integration",
          "value": "Display and alarm integration with vehicle-control, event-recorder, data-gateway, and other onboard systems"
        },
        {
          "@type": "PropertyValue",
          "name": "Display and Onboard Integration · Locomotive power",
          "value": "DC46–160 V locomotive input"
        },
        {
          "@type": "PropertyValue",
          "name": "Optional AI Compute Base · AI behavior analytics",
          "value": "Optional local AI processing for selected locomotive engineer-monitoring functions"
        },
        {
          "@type": "PropertyValue",
          "name": "Optional AI Compute Base · Switching and interfaces",
          "value": "Integrated onboard switching, locking circular connectors and CAN/RS485 interfaces"
        }
      ]
    },
    {
      "@context": "https://schema.org",
      "@type": "FAQPage",
      "@id": "https://megafeis.com/split-cab-display#faq",
      "name": "Split Cab Display FAQ",
      "mainEntity": [
        {
          "@type": "Question",
          "name": "Why cannot a standard industrial tablet replace a dedicated locomotive onboard tablet?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "A standard industrial tablet may not include the locomotive power, vibration, temperature, and EMC design needed for the vehicle environment. It may also lack the vehicle interfaces, common timing, and event-record workflow required by an integrated onboard system."
          }
        },
        {
          "@type": "Question",
          "name": "How do the tablet base and onboard computer divide computing work?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "The standard base provides switching, power, and device access. The AI-enhanced base can support lightweight cab-monitoring functions, while the onboard computer performs deeper track-ahead and running-gear analytics."
          }
        },
        {
          "@type": "Question",
          "name": "How is event data handled during a communications outage?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "When configured with local storage, the tablet can retain event imagery in disconnected territory and synchronize records through the onboard data gateway after connectivity returns."
          }
        }
      ]
    },
    {
      "@context": "https://schema.org",
      "@type": "WebPage",
      "@id": "https://megafeis.com/split-cab-display#webpage",
      "url": "https://megafeis.com/split-cab-display",
      "name": "Split Cab Display",
      "description": "Split cab-display terminal for locomotive operating data, track-ahead and running-gear event imagery, equipment alarms, live video, and offline record review.",
      "inLanguage": "en",
      "isPartOf": {
        "@id": "https://megafeis.com/#website"
      },
      "mainEntity": {
        "@id": "https://megafeis.com/split-cab-display#product"
      }
    },
    {
      "@context": "https://schema.org",
      "@type": "BreadcrumbList",
      "@id": "https://megafeis.com/split-cab-display#breadcrumb",
      "itemListElement": [
        {
          "@type": "ListItem",
          "position": 1,
          "name": "Home",
          "item": "https://megafeis.com/"
        },
        {
          "@type": "ListItem",
          "position": 2,
          "name": "Split Cab Display",
          "item": "https://megafeis.com/split-cab-display"
        }
      ]
    }
  ]
}
